To conduct these tests, we have walk-in test chambers with volumes of up to 70 m³, in which the efficiency of air purification devices and technologies can be researched and verified under real-world and practical conditions. During the test, these chambers can be exposed to gases, organic substances, or aerosols.
In addition to discontinuous sampling techniques for detecting analytes, we utilize online measurement techniques that enable the determination of kinetics before, during, and after the purification stages. More than a thousand substances and gases can be provided in our test chambers ‒ either individually or in mixtures ‒ to evaluate air purification concepts. Suitable, quality-assured analytical methods are available for all test substances. Synthetic nanoparticles can also be used in aerosolized form for device testing. To simulate airborne viruses and bacteria, we use surrogates. These are introduced into the test chamber atmosphere as bioaerosols and nebulized. Their decay rate over the test period serves as an indicator of the effectiveness of the cleaning technology and device.
In our accredited laboratory, we can conduct tests to determine key performance metrics such as the Clean Air Delivery Rate (CADR), Hygienic Air Delivery Rate (HADR), and Constant Challenge Test (CCT).
As part of a project funded by the German Social Accident Insurance (DGUV), we have developed a testing standard for the uniform evaluation of air purifier efficiency.