Emissions from Materials and Products

We investigate the emission behavior of everyday and household items, as well as construction materials, furniture, electrical appliances and all products and materials which are used indoors (decorative items, toys, etc.). In doing so, we measure the broadest possible spectrum of airborne contaminants: from very volatile and volatile organic compounds (VVOCs, VOCs) to semi-volatile organic compounds (SVOCs), as well as particles and (bio)aerosols. In addition, we evaluate the functionality and efficiency of technologies and devices designed to reduce airborne contaminants in indoor air, such as air purifiers.

 

The department of Materials Analysis and Indoor Chemistry is equipped with a comprehensive range of technical facilities, including numerous emission test chambers and a full suite of analytical methods. The laboratory is accredited according to DIN EN ISO/IEC 17025:2018.

Emissions testing for the following target substances/substance groups

  • VVOC/VOC/SVOC: Very Volatile, Volatile, and Semi-Volatile Organic Compounds by TD-GC/MS in accordance with DIN ISO 16000-6
  • VOC: Qualitative determination using dynamic or static headspace GC/MS
  • Acrolein (2-propenal) by TD-GC/MS in accordance with DIN ISO 16000-3 (draft)
  • Formic acid and acetic acid by IC in accordance with VDI 4301-7
  • Low-volatility aldehydes by HPLC/DAD in accordance with DIN ISO 16000-3 (draft)
  • PFAS: Per- and polyfluoroalkyl substances (PFAS), including perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), by TD-GC/TQ
  • N-nitrosamines by HPLC-MS/MS
  • Ammonia by IC

Continuous online monitoring (real-time data collection)

  • TVOC: by photoacoustic infrared spectroscopy (PAS)
  • Ozone (O₃): by non-dispersive UV absorption method (NDUV)
  • Ammonia using photoacoustic spectroscopy (PAS) in conjunction with a quantum cascade laser
  • Nitrogen oxides (NOx) using the cross-flow-modulated chemiluminescence method
  • Sulfur dioxide (SO₂) via UV fluorescence (UVF)
  • Carbon monoxide (CO) using the non-dispersive infrared absorption method (NDIR)
  • Carbon monoxide (CO) using photoacoustic infrared spectroscopy (PAS)
  • Carbon dioxide (CO₂) using photoacoustic infrared spectroscopy (PAS)
  • Ultrafine particles (5.6–560 nm): continuously, using an electrical mobility measurement method
  • Fine particles (0.3–10 µm): continuously, using optical single-particle counting
  • Formaldehyde (HCHO): using photoacoustic infrared spectroscopy (PAS)
  • Oxygen (O₂): continuously, via electrochemical measurement
  • Bioaerosols (MS2 phages): measured using impingement and microbiological analysis via the two-layer agar method

Emissions testing in accordance with national and international standards and specifications

Emissions testing of materials and construction products in accordance with the ISO 16000 series

  • DIN ISO 16000-3: Indoor air contaminants ‒ Part 3: Measurement of formaldehyde and other carbonyl compounds in indoor air and in test chambers ‒ Sampling with a pump.
  • DIN ISO 16000-6: Indoor air pollutants ‒ Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor air and test chamber air by active sampling on adsorption tubes, thermal desorption, and gas chromatography with MS or MS-FID.
  • DIN EN ISO 16000-9: Indoor air pollutants ‒ Part 9: Determination of emissions of volatile organic compounds from samples of building products and furnishings ‒ Emission test chamber method.
  • DIN EN ISO 16000-10: Indoor air pollutants ‒ Part 10: Determination of emissions of volatile organic compounds from building products and furnishings ‒ Emission test cell method.
  • DIN EN ISO 16000-11: Indoor air pollutants ‒ Part 11: Determination of emissions of volatile organic compounds from samples of construction products and furnishings ‒ Sampling, storage of samples, and preparation of test specimens.

Emissions testing of materials and construction products in accordance with European standards

  • DIN EN 16516: Construction products: Assessment of the release of hazardous substances ‒ Determination of emissions into indoor air

National standards

  • AgBB Assessment Scheme: Assessment Scheme of the Committee for the Health Assessment of Construction Products (AgBB): Requirements for indoor air quality in buildings: Health assessment of emissions of volatile organic compounds (VVOCs, VOCs, and SVOCs) from construction products, including odor assessment upon request.
  • MVV TB (Model Administrative Regulation on Technical Building Regulations) and ABG (Requirements for Building Structures Regarding Health Protection)
  • ChemVerbotsV: Formaldehyde emissions from building products; Ordinance on Prohibitions and Restrictions on the Placing on the Market and the Supply of Certain Substances, Mixtures, and Articles pursuant to the Chemicals Act; Chemicals Prohibition Ordinance 

Quality marks

  • GEV test method for determining volatile organic compounds for classification in the EMICODE® system, classification according to emission behavior into EMICODE® EC1PLUS, EMICODE® EC 1, and EMICODE® EC 2, published by the Association for the Control of Emissions in Products for Flooring Installation, Adhesives and Building Materials (GEV)
  • RAL Quality Mark “Golden M”, test basis RAL-GZ 430, General Quality and Testing Specifications for Furniture, including odor assessment, German Furniture Quality Association (Deutsche Gütegemeinschaft Möbel e. V.)
  • The German “Blue Angel” environmental label for various products, including
    • DE-UZ 12a, Low-emission and low-pollutant paints
    • DE-UZ 38, Low-emission furniture and slatted frames made of wood and wood-based materials
    • DE-UZ 76, Building and furniture panels for interior construction
    • DE-UZ 113, Low-emission flooring adhesives and other installation materials
    • DE-UZ 117, Low-emission upholstered furniture
    • DE-UZ 119, Mattresses
    • DE-UZ 120, Resilient Floor Coverings
    • DE-UZ 123, Low-emission sealants for interior use
    • DE-UZ 128, Low-Emission Textile Floor Coverings
    • DE-UZ 132, Low-Emission Thermal Insulation Materials and Suspended Ceilings for Interior Applications
    • DE-UZ 148, Leather
    • DE-UZ 156, Low-Emission Underlayments for Floor Coverings
    • DE-UZ 176, Low-Emission Floor Coverings, Panels, and Doors Made of Wood and Wood-Based Materials for Interior Use
    • DE-UZ 177, Recycled Toner and Ink Cartridges for Printers, Copiers, and Multifunction Devices
    • DE-UZ 198, Low-emission interior plasters
    • DE-UZ 219, Office equipment with printing capabilities (printers and multifunction devices)
  • “pure life” quality label for low-emission PU insulation materials, Fraunhofer WKI – Test Standard, WKI-PS-EPUD-001
  • Award criteria “Tested for Harmful Substances” for interior emulsion paints, WKI test specification WKI-PS-DIF-003
  • Assessment of building products based on the DGNB criteria of the German Sustainable Building Council (DGNB e. V.)
  • Quality Association of German Pre-fabrication (QDF)
    • QDF Guideline for Wood-Based Materials “QDF Requirements for Wood-Based Materials”
    • QDF Guideline ‒ Indoor Air Measurements “Conducting Measurements of Formaldehyde and Volatile Organic Compounds (VOCs) in Turnkey Homes”

European and international regulations/quality marks

  • French VOC Regulation (DEVL1104875A), classification of building materials into emission classes A+, A, B, C
  • Austrian Ecolabel, Guideline UZ 07 for wood and wood-based materials
  • Belgian VOC requirements, Royal Decree establishing limit values for indoor emissions from building products for certain intended uses
  • Danish Indoor Climate Labeling (DICL) plus odor assessment, labeling system for emissions from furniture, building products, and furnishings
  • M1 classification of furniture and building products according to the specifications of the Finnish certification body Building Information Foundation RTS sr, Finnish emission classification of building materials and furniture, Protocol for Chemical and Sensory Testing of Building Materials, including odor assessment
  • Italian environmental criteria CAM (Criteri Ambientali Minimi): Evaluation of emissions 
  • U.S. building certification program LEED (Leadership in Energy and Environmental Design): Assessment of building materials
  • British certification program BREEAM (Building Research Establishment Environmental Assessment Method): Assessment of building products based on BREEAM requirements
  • California standard for evaluating VOC emissions, California Specification 01350, Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers, evaluation in accordance with Proposition 65. 

Product and material testing

  • VOC: Qualitative determination of extractable volatile organic compounds (VOCs) using solvent extraction and GC/MS
  • Elemental Analysis: Quantitative determination of elements (including As, Cd, Cr, Cu, Pb, Hg) using ICP/MS
  • Plasticizers: Quantitative determination of plasticizers (phthalates, adipates, citrates) in plastics and consumer goods
  • Residual monomers and photoinitiators: Quantitative determination in UV-curable paints and coatings
  • Surface- and photocatalytically active materials: Investigation of functionality
  • PFAS in materials and dust: Quantitative determination of extractable per- and polyfluorinated alkyl substances (PFAS), including perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS), using LC/TQ
  • Wallpaper: Tests in accordance with
    • RAL-GZ 479: Quality assurance for wallpaper
    • DIN EN 15102: Decorative wall coverings—Rolls
  • Metals: Determination by total digestion extraction
  • Phthalates in plastics and coatings
  • Photocatalytic surfaces: Testing of cleaning performance